Probe design for measuring total temperature of combustor outlet based on water cooling
燃烧、传热、传质|更新时间:2026-07-07
|
Probe design for measuring total temperature of combustor outlet based on water cooling
Probe design for measuring total temperature of combustor outlet based on water cooling
航空动力学报2018年33卷第9期 页码:2084-2092
作者机构:
1. School of Energy and Power Engineering,Beijing University of Aeronautics and Astronautics,Beijing,100191
2. School of Aviation Operations and Services,Aviation University of Air Force,Changchun,China,130022
作者简介:
基金信息:
National Natural Science Foundation (9174110013);Aviation Power Fund (614B090310)National Natural Science Foundation (9174110013);Aviation Power Fund (614B090310)
ZHAO Kai, LI Feng, LU Fuguo, ZHOU Tao, YANG Hongyu. Probe design for measuring total temperature of combustor outlet based on water cooling[J]. 航空动力学报, 2018, 33(9): 2084-2092.
doi: 10.13224/j.cnki.jasp.2018.09.005
ZHAO Kai, LI Feng, LU Fuguo, ZHOU Tao, YANG Hongyu. Probe design for measuring total temperature of combustor outlet based on water cooling[J]. 航空动力学报, 2018, 33(9): 2084-2092.DOI: 10.13224/j.cnki.jasp.2018.09.005.
doi: 10.13224/j.cnki.jasp.2018.09.005DOI:
Probe design for measuring total temperature of combustor outlet based on water cooling
a kind of high-temperature and water cooling thermocouple was designed. The main factors affecting the results of thermocouple measurement were analyzed after numerical simulation. Results showed that the high-temperature water cooling thermocouple can achieve high temperature measurement under the condition of 2400K. With the increase of the distance between the water cooling structure and the stagnation cover
the temperature measurement result was more accurate
and the increase in the area ratio of the inlet and outlet of the stagnation cover within a reasonable range can make the measurement results more accurate. The surface emissivity of the measuring point had a great influence on the radiation error. The pressure and flow rate of cooling water can be effectively reduced after adding zirconia coating onto the surface of the rake body.
Abstract
To obtain the outlet temperature of combustor
a kind of high-temperature and water cooling thermocouple was designed. The main factors affecting the results of thermocouple measurement were analyzed after numerical simulation. Results showed that the high-temperature water cooling thermocouple can achieve high temperature measurement under the condition of 2400K. With the increase of the distance between the water cooling structure and the stagnation cover
the temperature measurement result was more accurate
and the increase in the area ratio of the inlet and outlet of the stagnation cover within a reasonable range can make the measurement results more accurate. The surface emissivity of the measuring point had a great influence on the radiation error. The pressure and flow rate of cooling water can be effectively reduced after adding zirconia coating onto the surface of the rake body.