A highly loaded fan with the insufficiency of the stall margin in the states of off-design speed was studied. After numerical simulation of three dimensional flow using commercially available CFD code NUMECA
the change of aerodynamic performance of a variable inlet guide vane (VIGV)
and the improvement method of low-speed performance of the fan were investigated
when the VIGVs front and back vane parts can be rotated in large range of angle. Results of numerical simulation indicated that the camber angel of the VIGV was one of the most important influential factors to the performance of the VIGV. The front vane part of the VIGV was rotated at some angle
the actual camber angle of the vane was reduced
helping to delay flow separation on the vanes suction surface
and broaden the VIGVs adjustable angle with a low-loss level. Besides
the VIGV was not sensitive to the position of a slot between the two vane parts
if both of the vane parts were rotated with proper angles. The VIGV improved the adiabatic efficiency of the highly loaded fan under the off-designed conditions
the adiabatic efficiencies were improved by 2.04%
5.48%
6.18% and 6.82% at 90% speed
80% speed
70% speed and 60% speed. Because the throat line of the fan was further away from the throttle line
the fans surge margin was expanded obviously at off-speed.