The measurement system of atomization field was built on a centrifugal fuel slinger test bench. A suction hood with multi-well plate was used to prevent the oil mist spill
and its flow field was calculated by simulation. Performance parameters such as fuel droplet space distribution
size distribution and atomization cone angle were measured by pulsed digital holography under different rotary speeds. Results indicated that the radial velocity of suction hood was uniform
the velocity field near the fuel slinger was an order of magnitude lower than the droplet velocity
so its influence on the atomization field was small. The 20 μm peak droplet size of atomization field accounted for 20%-30%. With increase of the rotary speed
droplet size Sauter mean diameter (SMD) gradually decreased
atomization field was centralized to axial direction and atomization cone angle was reduced. At the same rotary speed
with the increasing distance away from the nozzle outlet