北京信息科技大学 机构 机电工程学院,北京,100192
[ "黄正军,硕士研究生," ]
[ "刘泉,教授,硕士生导师," ]
纸质出版:2025
移动端阅览
黄正军, 刘泉, 郝育新. 永磁同步直驱风力发电机结构改进研究[J]. 机械科学与技术, 2025,44(8):1301-1307.
黄正军, 刘泉, 郝育新. Research on Structure Improvement of Permanent Magnet Synchronous Direct-drive Wind Turbine Generator[J]. Mechanical Science and Technology for Aerospace Engineering, 2025, 44(8): 1301-1307.
黄正军, 刘泉, 郝育新. 永磁同步直驱风力发电机结构改进研究[J]. 机械科学与技术, 2025,44(8):1301-1307. DOI: 10.13433/j.cnki.1003-8728.20230288.
黄正军, 刘泉, 郝育新. Research on Structure Improvement of Permanent Magnet Synchronous Direct-drive Wind Turbine Generator[J]. Mechanical Science and Technology for Aerospace Engineering, 2025, 44(8): 1301-1307. DOI: 10.13433/j.cnki.1003-8728.20230288.
针对直驱型风力发电机组结构载荷分布不合理,塔筒因强度不足而折断的问题,从直驱型风力发电机组载荷分布问题出发,对直驱型风力发电机组结构改进。利用有限元软件对改进前后的结构进行静力分析、预应力模态分析。对比分析结果发现,改进后相比改进前最大位移减少了532.74 mm,减少幅度约为37.68%,相对塔筒高度位移减少了0.33%。改进后最大应力为141.74 MPa,相对改进前减少了81.43 MPa,减少幅度约为36.48%,占许用应力部分减少了14.81%;改进前后塔筒结构振型相差较小,振型规律相同;改进后塔筒结构自振频率比改进前有所增加,但最大变化仅为0.00008 Hz。
In view of the unreasonable structural load distribution of direct-drive wind turbines and the frequent occurrence of tower breaking accidents
this paper improves the structure of direct-drive wind turbines based on the load distribution of direct-drive wind turbines. The mechanical analysis on the structures before and after the improvement is conducted
and the loaddistribution is calculated. The static analysis and prestress modal analysis of the structures before and after the improvement are carried out by using the finite element software. The comparative analysis results show that the maximum displacement after the improvement is reduced by 532.74 mm
the reduction is about 37.68%
and the relative tower height displacement is reduced by 0.33%. The maximum stress after improvement is 141.74 MPa
which is 81.43 MPa lower than that before improvement
with a decrease of about 36.48% and a decrease of 14.81% in the allowable stress. The vibration mode difference of tower drum structures before and after improvement is small
and the vibration mode rule is the same. After the improvement
the natural vibration frequency of the tower structure has increased
but the maximum change is only 0.000 08 Hz.