1. I 国网许继组团福州天宇电气有限公司,福州,350000
2. 2福州大学电气工程与自动化学院,福州,350108
纸质出版:2021
移动端阅览
穆岳, 陈伯根, 蔡锋, 等. 电力变压器三维瞬态漏磁场及电动力仿真分析[J]. 哈尔滨理工大学学报, 2021,26(5):104-113.
MU Long, CHEN Bo-gen, CAI Feng, et al. Simulation and Analysis of 3 D Transient Leakage Magnetic Field and Electromotive Force of Power Transformer[J]. 2021, 26(5): 104-113.
穆岳, 陈伯根, 蔡锋, 等. 电力变压器三维瞬态漏磁场及电动力仿真分析[J]. 哈尔滨理工大学学报, 2021,26(5):104-113. DOI: 10.15938/j.jhust.2021.05.014.
MU Long, CHEN Bo-gen, CAI Feng, et al. Simulation and Analysis of 3 D Transient Leakage Magnetic Field and Electromotive Force of Power Transformer[J]. 2021, 26(5): 104-113. DOI: 10.15938/j.jhust.2021.05.014.
摘 要:为了分析变压器绕组在短路冲击下的瞬态磁场及瞬态电动力特性,依据变压器绕组的屈磁场理论和短路电动力的计算原理,利用计算电磁场的有限元分析软件,以1台SSZl 1 - 50000/110三绕组电力变压器为研究对象,建立了变压器绕组的仿真模型和短路计算方程,进行了变压器瞬态涡磁场和瞬态短路电动力计算仿真分析。 在变压器高中运行方式的中压侧绕组出现接地短路故障时,计算出绕组瞬态漏磁场,以及绕组轴向、辐向瞬态短路电动力的分布规律。仿真结果表明, 绕组在短路过程中,漏磁场、电动力分布与时间和空间有关,并均在t = 0. 01 s时刻出现最大值。 在任意时刻下,轴向磁感应强度,两侧小,中间大;中压和高压绕组之间的辐向磁感应强度近似为"A" 形。铁芯窗内侧与铁芯窗外侧绕组的辐向电动力的分布规律不同,辐向电动力铁芯窗内侧比铁芯窗外侧数值大。绕组轴向电动力,近似中心对称分布,均表现为两侧电动力数值最大,靠近绕组中部最小。 此研究为防止变压器绕组变形和改进设计提供参考。
In order to analyze the transient magnetic field and transient electrodynamic characteristics of transformer windings under shorL-circuit impact
according to the Lheo1-y of leakage magnetic field of transformer windings and the principle of calculation of short-circuit electrodynamics
using the finite element analysis software for calculating electromagnetic fields
a SSZl 1 - 50000/110 the three-winding power n·ansfo1mer is the research object
Lhe simulation model and short-circuit calculation equation of the transformer winding are established
and the simulation analysis of the transient leakage magnetic field and transient short-circuit electromotive force of the transformer is c打ried out. When the medium-voltage side winding of the transformer high-medium operation mode has a ground shmt-circuit fault
the transient leakage magnetic field of the winding and the disn-ibution law of the axial and radial transienl short-circuit electromotive force of the winding are calculated. The simulation results showthat during the short-circuit process of the winding
the leakage magnetic field and the electromotive force distribution ru·e related to time and space
and all appear at the maximum value at t = 0. 01 s. At any time
the axial magnetic induction intensity is small on both sides and large in the middle; Lhe radial magnetic induction intensity between the medium-voltage and high-voltage windings is approximately "A" shaped. The distribution law of the radial electrodynamic direction of the \vindings on the inner side of the iron core
vindow and the outer side of the iron core window is different The axial electromotive force of the winding is approximately symmeb-ically distributed in the center
and the elecb·omotive force on both sides is the largest
and the smallest is near the middle of the winding. This study provides a reference for preventing transformer winding defo1mation and improving design.