WANG Fang, WANG Peng-hao, XU Hong-xiang. emperature and Concentration Analysis of Induced Ventilation System in Large Broiler House[J]. 2019, 24(1): 29-33.
WANG Fang, WANG Peng-hao, XU Hong-xiang. emperature and Concentration Analysis of Induced Ventilation System in Large Broiler House[J]. 2019, 24(1): 29-33.DOI: 1015938/jjhust201901005.
Abstract:Aiming at the problem of the high concentration ofharmful gases and poor air distribution in an intelligent control broiler housein China
the mathematical and physical models of induced ventilation systemwere established.According to the finite volume method
the corresponding boundary conditionswere set up.Numerical simulation has been done by Airpak. It is analyzed how to set theparameter of induced fan and factors in broiler house
including the velocity
temperature
and ammonia concentration. The results prove that the induced ventilation method caneffectively solve the problem of high temperature and ammonia concentration inbroiler house
achieve the better ventilation effect
and improve theenvironment quality in broiler house when the induced fan is set at 15° of thedeclination