LIU Kai, ZHANG Bao-cheng, CAI Jiu-ju, et al. Experimental study on outlet temperature field for combustor of heavy-duty gas turbine[J]. 2010, 25(1).DOI:
Experimental study on combustor temperature field of heavy-duty gas turbine(E) was finished on high-pressure test system.Experimental results indicate that: circular temperature distribution coefficient of combustor is 0.2538
and radial temperature distribution coefficient is 0.1312
all of which do not meet the design requirements.Through adjustment of mix-holes size and layout of chamber
and increase of the penetration depth and intensity of mixing
the circular temperature distribution coefficient decreased to 0.2164
radial temperature distribution coefficient decreased to 0.0897
approaching the design target.The results have important significance for the experiment of similar combustors.